{"id":479,"date":"2024-10-28T13:41:40","date_gmt":"2024-10-28T10:41:40","guid":{"rendered":"https:\/\/dymet.ee\/?page_id=479"},"modified":"2025-06-05T10:51:25","modified_gmt":"2025-06-05T07:51:25","slug":"k6-round-6-mm-nozzle-insert","status":"publish","type":"page","link":"https:\/\/dymet.ee\/de\/products-2\/k6-round-6-mm-nozzle-insert\/","title":{"rendered":"K6 round 6 mm nozzle insert"},"content":{"rendered":"\n\n\n<p><strong>Instructions for Using the K6 Supersonic Nozzle Insert<br><em>For all type 6 mm round nozzle  in Low-Pressure Cold Spray Equipment<\/em><\/strong><\/p>\n\n\n\n<div id=\"attachment_622\" style=\"width: 336px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-622\" class=\" wp-image-622\" src=\"https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3994-225x300.jpg\" alt=\"K6 supersonic nozzle insert for cold spray systems Titomik, Dymet, CSM 108.2\" width=\"326\" height=\"435\" srcset=\"https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3994-225x300.jpg 225w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3994-768x1024.jpg 768w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3994-1152x1536.jpg 1152w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3994-1536x2048.jpg 1536w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3994-113x150.jpg 113w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3994-450x600.jpg 450w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3994-600x800.jpg 600w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3994-scaled.jpg 1920w\" sizes=\"auto, (max-width: 326px) 100vw, 326px\" \/><p id=\"caption-attachment-622\" class=\"wp-caption-text\">Supersonic K6 insert for low-pressure cold spray 10 pcs. kit<\/p><\/div>\n<ol data-start=\"234\" data-end=\"985\">\n<li data-start=\"234\" data-end=\"411\">\n<p data-start=\"237\" data-end=\"411\"><strong data-start=\"237\" data-end=\"261\">Correct Installation<\/strong><br data-start=\"261\" data-end=\"264\" \/>The K6 insert has one end with a smaller diameter. This end must be fully inserted into the nozzle body and secured by tightening the set screw.<\/p>\n<div id=\"attachment_621\" style=\"width: 310px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-621\" class=\"size-medium wp-image-621\" src=\"https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3996-300x225.jpg\" alt=\"How to install K6 nozzle insert for cold spray equipment\" width=\"300\" height=\"225\" srcset=\"https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3996-300x225.jpg 300w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3996-1024x768.jpg 1024w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3996-768x576.jpg 768w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3996-1536x1152.jpg 1536w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3996-150x113.jpg 150w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3996-200x150.jpg 200w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3996-600x450.jpg 600w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3996.jpg 2016w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-621\" class=\"wp-caption-text\">\u00a0 Proper installation procedure of the K6 insert<\/p><\/div>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-620\" src=\"https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3997-300x171.jpg\" alt=\"K6 supersonic nozzle insert for cold spray systems Dymet, Titomic, Dycomet\" width=\"300\" height=\"171\" srcset=\"https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3997-300x171.jpg 300w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3997-1024x582.jpg 1024w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3997-768x437.jpg 768w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3997-1536x873.jpg 1536w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3997-150x85.jpg 150w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3997-250x142.jpg 250w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3997-600x341.jpg 600w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3997.jpg 1613w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<\/li>\n<li data-start=\"413\" data-end=\"693\">\n<p data-start=\"416\" data-end=\"693\"><strong data-start=\"416\" data-end=\"442\">Extending Service Life<\/strong><br data-start=\"442\" data-end=\"445\" \/>To ensure even wear and extend the service life of the K6 nozzle insert, rotate it by <strong data-start=\"534\" data-end=\"598\">15\u00b0 from its original position every 20 minutes of operation<\/strong>. This helps to distribute internal erosion more evenly and prolong the insert&#8217;s functionality.<\/p>\n<\/li>\n<li data-start=\"695\" data-end=\"985\">\n<p data-start=\"698\" data-end=\"985\"><strong data-start=\"698\" data-end=\"728\">When to Replace the Insert<\/strong><br data-start=\"728\" data-end=\"731\" \/>Replace the K6 nozzle insert when internal holes or erosion marks begin to appear.<br data-start=\"816\" data-end=\"819\" \/><strong data-start=\"822\" data-end=\"834\">Warning:<\/strong> If the insert is not replaced in time, these holes may grow significantly larger, leading to decreased performance and potential damage to the nozzle.<\/p>\n<div id=\"attachment_623\" style=\"width: 310px\" class=\"wp-caption alignnone\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-623\" class=\"size-medium wp-image-623\" src=\"https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3999-300x184.jpg\" alt=\"Example of worn K6 nozzle insert after usage\" width=\"300\" height=\"184\" srcset=\"https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3999-300x184.jpg 300w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3999-1024x627.jpg 1024w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3999-768x470.jpg 768w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3999-150x92.jpg 150w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3999-245x150.jpg 245w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3999-600x367.jpg 600w, https:\/\/dymet.ee\/wp-content\/uploads\/2025\/06\/IMG_3999.jpg 1445w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-623\" class=\"wp-caption-text\">Example of worn K6 nozzle insert after usage<\/p><\/div>\n<\/li>\n<\/ol>\n","protected":false},"excerpt":{"rendered":"<p>Instructions for Using the K6 Supersonic Nozzle InsertFor all type 6 mm round nozzle in Low-Pressure Cold Spray Equipment Correct InstallationThe K6 insert has one end with a smaller diameter. This end must be fully inserted into the nozzle body and secured by tightening the set screw. Extending Service LifeTo \u2026 <a class=\"continue-reading-link\" href=\"https:\/\/dymet.ee\/de\/products-2\/k6-round-6-mm-nozzle-insert\/\"> Continue reading <span class=\"meta-nav\">&rarr; <\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":137,"menu_order":100,"comment_status":"closed","ping_status":"closed","template":"","meta":{"two_page_speed":[],"footnotes":""},"class_list":["post-479","page","type-page","status-publish","hentry"],"translation":{"provider":"WPGlobus","version":"3.0.2","language":"de","enabled_languages":["en","ee","fi","ru","fr","es","it","de"],"languages":{"en":{"title":true,"content":true,"excerpt":false},"ee":{"title":false,"content":false,"excerpt":false},"fi":{"title":false,"content":false,"excerpt":false},"ru":{"title":false,"content":false,"excerpt":false},"fr":{"title":false,"content":false,"excerpt":false},"es":{"title":false,"content":false,"excerpt":false},"it":{"title":false,"content":false,"excerpt":false},"de":{"title":false,"content":false,"excerpt":false}}},"_links":{"self":[{"href":"https:\/\/dymet.ee\/de\/wp-json\/wp\/v2\/pages\/479","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dymet.ee\/de\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/dymet.ee\/de\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/dymet.ee\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dymet.ee\/de\/wp-json\/wp\/v2\/comments?post=479"}],"version-history":[{"count":2,"href":"https:\/\/dymet.ee\/de\/wp-json\/wp\/v2\/pages\/479\/revisions"}],"predecessor-version":[{"id":627,"href":"https:\/\/dymet.ee\/de\/wp-json\/wp\/v2\/pages\/479\/revisions\/627"}],"up":[{"embeddable":true,"href":"https:\/\/dymet.ee\/de\/wp-json\/wp\/v2\/pages\/137"}],"wp:attachment":[{"href":"https:\/\/dymet.ee\/de\/wp-json\/wp\/v2\/media?parent=479"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}